9 pages, 45 questions, 1 questions with responses, 1 total responses,    0    0
bee_energy
Jawaharlal Nehru Technological University (JNTUH), Hyderabad
+Fave Message
 Home > bee_energy >

Formatting page ...

Question bank for Energy Managers & Energy Auditors Chapter 3.3: Compressed Air System Part I: Objective type questions and answers 1. Which of the following type does Screw compressor belongs to? a) Positive displacement compressor c) Both a & b 2. b) Dynamic compressors d) None of the above The compressor capacity of a reciprocating compressor is directly proportional to __ a) Speed 3. b) Pressure b) Same c) Higher d) None b) Same c) Higher d) None b) Higher c) moderate d) None The volumetric efficiency of the compressor ______ with the increase in altitude of place a) increases 8. d) 10 50 cfm The compression ratios for axial flow compressors are ____. a) Lesser 7. c) Above 10ooo cfm The discharge temperature of two stage compressor compared to single stage one is ____ a) Lesser 6. b) 200 500 cfm The specific power consumption of non lubricated compressor compared to lubricated type is ____ a) Lesser 5. d) All Vertical type reciprocating compressors are used in the capacity range of _____ a) 50 150 cfm 4. c) Volume b) decreases c) does not change d) None The ratio of isothermal power to actual measured input power of a compressor is known as: a) Isothermal efficiency b) Volumetric Efficiency c) Barometric efficiency d) None 9. The basic function of air dryer in a compressor is: a. prevent dust from entering compressor b. storage and smoothening pulsating air output c. reduce the temperature of the air before it enters the next state to increase efficiency d. to remove remaining traces of moisture after after-cooler 10. For every 4 C raise in air inlet temperature of an air compressor, the power consumption will increases by_____ a) 2% 11. c) 3% d) 4% The percentage increase in power consumption of a compressor with suction side air filter and with the pressure drop across the filter of 200 mmWc is ____ a) 1.0% 12. b) 1% b) 3% c) 2.4% d) 1.6% Which of the statement is True for centrifugal compressors? a) The compressor should not be operated at full load b) The compressor should be operated at shut off pressure c) The compressor should not be operated with inlet-guide vane control 3.3 Compressed air system - revised (table format) 17

Formatting page ...

Top Contributors
to this ResPaper
(answers/comments)


Bhautik Parmar

(1)

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

 

  Print intermediate debugging step

Show debugging info


 


Tags : Bureau of Energy Efficiency, BEE, National Productivity Council of India, NPC, Energy Audit, Certified Energy Manager, Certified Energy Auditor, EM & EA, bee papers, bee sample papers, bee books, portal for bee india, bee question bank, bee question papers with answers, bee model test papers, solved board question papers of last year, previous years solved question papers, free online solved question paper, india sample questions papers, last 10 years papers, guess sample questions papers, important questions, specimen / mock papers, 2020, 2019, 2018, 2017, 2016, 2015, 2014, 2013, 2012, 2011, 2010, 2009, 2008, 2007, 2006, 2005.  

© 2010 - 2024 ResPaper. Terms of ServiceContact Us Advertise with us

 

bee_energy chat