Trending ▼   ResFinder  

14th National Certification Exam Energy Managers & Auditors AUGUST 2013 Paper 1

17 pages, 76 questions, 4 questions with responses, 4 total responses,    0    0
bee_energy
Jawaharlal Nehru Technological University (JNTUH), Hyderabad
+Fave Message
 Home > bee_energy >

Formatting page ...

Paper 1 Set A Solutions 14th NATIONAL CERTIFICATION EXAMINATION FOR ENERGY MANAGERS & ENERGY AUDITORS August, 2013 PAPER 1: General Aspects of Energy Management & Energy Audit Date: 24.08.2013 Section - I: a) b) c) Timings: 09:30-12:30 HRS Duration: 3 HRS OBJECTIVE TYPE Max. Marks: 150 Marks: 50 x 1 = 50 Answer all 50 questions Each question carries one mark Please hatch the appropriate oval in the OMR answer sheet with Black Pen or HB pencil, as per instructions As per Energy Conservation Act, 2001, a BEE Certified Energy Manger is required to be appointed/designated by the a) state designated agencies c) designated consumers b) all industrial consumers d) electrical distribution licensees The type of energy possessed by a charged capacitor is a) kinetic energy b) electrostatic c) potential d) magnetic The process of capturing CO2 from point sources and storing them is called __________. a) carbon sequestration c) carbon capture b) carbon sink d) carbon adsorption What is the heat content of 200 liters of water at 5 oC in terms of the basic unit of energy in kilojoules ? a) 3000 b) 2388 c) 1000 d) 4187 Nameplate kW rating of a motor indicates a) input to the motor c) no-load input to the motor b) rated output of the motor d) rated input to the motor Which of the following has the highest specific heat? a) lead b) mercury c) water d) alcohol What is the average conversion efficiency of a solar photo voltaic cell? a) 22% b)15% c) 98% d)50% 1 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions An indication of sensible heat content in air-water vapour mixture is a) wet bulb temperature c) density of air b) dew point temperature d) dry bulb temperature Which of the following statements with respect to Reserve / Production (R/P) ratio is true? a) b) c) d) is a constant once established varies every year with changes in production varies every year with changes in reserves varies every year with changes in production and reserves Which issue is not addressed by Integrated Energy Policy of India? a) b) c) d) consistency in pricing of energy scope for improving supply of energy from varied sources energy conservation, research and development removal of subsidies for energy across all sectors In inductive and resistive combination circuit, the resultant power factor under AC supply will be a) less than unity b) more than unity c) zero d) unity Which of the following statement is not true regarding energy security? a) b) c) d) impaired energy security can even reduce agricultural output energy security is strengthened by minimising dependence on imported energy diversifying energy supply from different countries weaken energy security increasing exploration to find oil and gas reserves improves energy security An energy policy at the plant level is to be preferably signed by a) chief executive c) energy auditor b) energy Manager d) chief executive with approval of state designated agency The energy benchmarking parameter for air conditioning equipment is a) kW/Ton of Refrigeration c) kW/m3 of chilled water b) kW/ kg of refrigerant handled d) kW/EER How much carbon dioxide emission will be reduced annually by replacing 60 Watt incandescent lamp with a 15 Watt CFL Lamp, if emission per unit is 1 kg CO2 per kWh and annual burning is 3000 hours? a) 45 ton b) 3 ton c) 0.135 ton d) 183 ton Which of the following statement is not correct regarding Demand Side Management (DSM)? a) agriculture and municipalities are potential areas for DSM activities b) savings accrued through DSM cannot be treated as avoided capacity on supply side 2 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions c) under DSM, demand can be shifted from peak to off peak hours thereby avoiding imported power during peak hours d) DSM programs may result in demand as well as energy reduction _________ considers impact of cash flow even after payback period a) net present value b) return on investment d) simple payback period b) sensitivity analysis Consider two competitive projects entailing investment of Rs.85,000/- . Project A returns Rs.50,000 at the end of each year, but Project B returns Rs.115,000 at the end of year 2. Which project is superior? a) Project A since it starts earning by end of first year itself and recovers cost before end of two years b) Project B since it offers higher return in two years c) both projects are equal in rank d) insufficient information __________ determines the project viability in response to changes in input parameters. a) Life cycle analysis c) b) Financial analysis d) Payback analysis Sensitivity analysis Which of the following is false? a) 1 calorie = 4.187 kJ c) 1000 kWh = 1 MWh b) 1 calorie = 4.187J d) 860 kcal = 1 kWh The annual electricity bill for a plant is Rs 110 lakhs and accounts for 38% of the total energy bill. Furthermore the total energy bill increases by 5% each year. The plant s annual energy bill at the end of the third year will be about ________ a) Rs 335 lakhs b) Rs 268 lakhs c) Rs 386 lakhs d) Rs 418 lakhs The retrofitting of a variable speed drive in a plant costs Rs 2 lakh. The annual savings is Rs 0.5 lakh. The maintenance cost is Rs. 5,000/year. The return on investment is a) 25% b) 22.5% c) 24% d) 27.5% For a project to be financially attractive, ROI must always be ___ than interest rate. a) lower b) higher c) equal d) no relation A sum of Rs 100,000 is deposited in a bank at the beginning of a year. The bank pays 10% interest annually. How much money will be in the bank account at the end of the fifth year, if no money is withdrawn? a) 161050 b) 150000 c) 155000 d) 160000 The technique used for scheduling the tasks and tracking of the progress of energy management projects through a bar chart is called 3 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions a) CPM b) Gantt chart c) CUSUM d) PERT ____________is a statistical technique which determines and quantifies the relationship between variables and enables standard equations to be established for energy consumption. a) linear regression analysis c) moving annual total b) time-dependent energy analysis d) CUSUM Which of the following is not an environmental issue of global significance? a) ozone layer depletion c) loss of Biodiversity b) global Warning d) suspended particulate Matter The power generation potential in mini hydro power plant for a water flow of 3 m3/sec with a head of 14 meters with system efficiency of 55% is a) 226.6 kW b) 76.4 kW c) 23.1 kW d) none of the above If the wind speed doubles, energy output from a wind turbine will be: a) 2 times higher b) 4 times higher c) 6 times higher d) 8 times higher Which of the following two statements are true regarding application of Kaizen for energy conservation? i) Kaizen events are structured for reduction of only energy wastes ii) Kaizen events engage workers in such a way so that they get involved in energy conservation efforts iii) Implementation of kaizen events takes place after review and approval of top management iv) In a Kaizen event, it may happen that small change in one area may result in significant savings in overall energy use a) ii & iv b) i & iv c) iii & iv d) i & iv The electrical power unit Giga Watt (GW) may be written as a) 1,000,000 MW b) 1,000 MW c) 1,000 kW d) 1,000,000 W Which of the following statements regarding TOD tariff is true? a) b) c) d) an incentive to induce user to draw more power during peak period discourages user from drawing more power during off peak period both a and b are true encourages user to shift load from peak period to off peak period The producer gas basically consists of a) Only CH4 b) CO & CH4 c) CO, H2 & CH4 d) Only CO & H2 The ozone layer in the stratosphere acts as an efficient filter for ____ 4 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions a) UV- B rays b) X-rays c) Gamma rays d) beta rays Which of the following macro factors is used in the sensitivity analysis of project finance? a) Change in tax rates c) Changes in debt: equity ratio b) Changes in maintenance cost d) Change in forms of financing Which among the following has the lowest Global Warming Potential? a) Perflurocarbon b) chloroflurocarbons c) methane d) nitrous oxide Which of the following statements is correct regarding float for an activity? a) b) c) d) Time between its earliest start time and earliest finish time Time between its latest start time and latest finish time Time between latest start time and earliest finish time Time between earliest finish time and latest finish time In a cumulative sum (CUSUM) chart, if the graph is going up, then a) nothing can be said b) actual and calculated energy consumption are the same c) energy consumption is reduced d) specific energy consumption is going up CO2 measurement in a Fyrite kit is based on a) Weight basis (dry) b) Volume basis (dry) c) Weight basis (wet) d) Volume basis (wet) The depletion of Ozone layer is caused mainly by _________ a) nitrous oxide b) carbon dioxide c) choloroflourocarbons d) methane gas Portable combustion analyzers may have in-built chemical cells for measurement of stack gas components. Which combination of chemical cells for measurement of stack gas components is not possible? a) CO, SOx, O2 b) CO2, O2 c) O2, NOr, SOx, CO d) O2, CO The Energy Conservation Act,2001 requires that all designated consumers should get energy audits conducted periodically by a) certified energy manager c) accredited energy auditor b) certified energy auditor d) state Designated Agencies The term missing in the following equation (kVA) 2 = (kVA cos phi) a) cos phi b) sin phi c) kVA sin phi 2 + ( ? ) 2 is d) kVArh The weight (kg) of the water vapour in each kg of dry air(kg/kg) is termed as : a) Specific Humidity b) relative humidity c) humidity d) saturation ratio 5 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions Which of the following tool is made use of to assess the input, conversion efficiency, output, losses, quantification of all material, energy and waste streams in a process or system? a) material balance c) material and energy balance b) energy balance d) Sankey diagram If feed of 100 tonnes per hour at 10% concentration is fed to an evaporator, the product obtained at 25% concentration is equal to ____ tonnes per hour. a) 25 b) 40 c) 50 d) 62.5 2000 kJ of heat is supplied to 500 kg of ice at 0 oC. If the latent heat of fusion of ice is 335 kJ/kg then the amount of ice in kg melted will be a) 1.49 b) 83.75 c) 5.97 d) None of the above An electric heater draws 5 kW of power for continuous hot water generation in an industry. How much quantity of water in litres per min can be heated from 30 oC to 85oC ignoring losses?. a) 1.3 b) 78.18 c) 275 d) none of the above The fixed energy consumption of a company is 2000 kWh per month. The line slope of the energy (y) versus production (x) chart is 0.3. The energy consumed in kWh per month for a production level of 80,000 tons/month is a) 24,000 kWh b) 24,200 kWh c) 26,000 kWh d) 38,000 kWh The major constituent of natural gas is a) Methane b) Ethane c) Propane d) Hydrogen . End of Section I . Section II: SHORT DESCRIPTIVE QUESTIONS (i) (ii) S-1 Marks: 8 x 5 = 40 Answer all Eight questions Each question carries Five marks The rating of a single phase electric geyser is 2000 Watts, at 230 Volt. Calculate: a) Rated current b) Resistance of the geyser in Ohms 6 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions c) Actual power drawn when the measured supply voltage is 210 Volts Answer: a)Rated Current of the Geyser, I = P/V= 2000/230 = 8.7 Ampere b)Resistance Value , R = V/I = 230/8.7= 26.4 Ohms c)Actual Power drawn at 210 Volts = (V/R)*V = (210/26.4) x210 = 1670 Watts OR (210/230)2 x 2000 = 1667 Watts S-2 A Diesel Generator performance trial gives specific generation of 3.5 kWh per liter of diesel. The cooling water loss and exhaust flue gas loss as percentage of fuel input are 28% and 32% respectively. The calorific value of diesel is 10,200 kcal/kg. The specific gravity of Diesel is 0.85. Calculate unaccounted loss as percentage of input energy. Ans CV of Diesel Heat in input diesel = 10,200 kcal/kg = 10,200 x 0.85 = 8670 kcal/litre Heat in kWh energy output = 3.5 x 860 = 3010 kcal/litre % of heat used for kWh output = 3010/8670 = 34.72 % Unaccounted loss = 100 (34.72+28+32) = 5.28 % S-3 A renovation and modernization (R&M) program of a 110 MW coal-fired thermal power plant was carried out to enhance the operating efficiency from 28% to 32%. The specific coal consumption was 0.7 kg/kWh before R&M. For 7000 hours of operation per year and assuming the coal quality remains the same, calculate a) the coal savings per year and b) the expected avoidance of CO2 into the atmosphere in Tons/year if the emission factor is 1.53 kg CO2/kg coal Ans a) Specific coal consumption after modernization = 28 x 0.7/32 = 0.6125 kg/kwh Annual savings = (0.7 0.6125) x110 x 1000 x 7000/1000 = 67,375 Tonnes per year b) CO2 emission reduction =67,375 x 1.53 = 103083.75 Tonnes of per year S-4 Ans Briefly compare NPV and IRR method of financial analysis. In NPV method, NPV is determined by assuming the discount rate (cost of capital). In IRR calculations, we set the NPV as zero and determine the discount rate (internal rate of return) which satisfies this condition. 7 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions The net present value method calculates the present value of all the yearly cash flows (i.e. capital costs and net savings) incurred or accrued throughout the life of a project and summates them. Costs are represented as negative value and savings as a positive value. The higher the net present value, the more attractive the proposed project. The calculation procedure for determining IRR is tedious (iterative) and usually requires a computer spreadsheet. The exact internal rate of return can be found by interpolation or plotting the net present value on a graph. If this discount rate is greater than current interest rate, the investment is sound. NPV is essentially a tool which enables number of different projects to be compared while IRR method is designed to assess whether a single project will achieve a target rate of return. The project is accepted if the net present value is positive and rejected if the net present value is negative. A negative net present value indicates that the project is not achieving the return standard and thus will cause an economic loss if implemented. A zero NPV is value neutral. In IRR, the criterion for selection among alternatives is to choose the investment with the highest rate of return. The internal rate of return figure cannot distinguish between lending and borrowing and hence a high internal rate of return need not necessarily be a desirable feature. Both the NPV and IRR takes into account the time value of money and it considers the cash flow stream in entire project life. S-5 Ans When the same quantity of heat is added to equal masses of iron and copper pieces, the temperature of iron piece rises by 15 OC. Calculate the rise in temperature of copper piece, if the specific heat of iron is 470 J / kg / OC and that of copper is 390 J / kg / oC. Mass of Iron x Sp. Heat Iron x 15 OC = Mass of Copper x Sp. Heat Copper x (Rise in Temp of Copper OC) Since mass of Iron = Mass of Copper Sp. Heat Iron x 15 OC = Sp. Heat Copper x (Rise in Temp of Copper OC) Sp. Heat of Iron = 470 J / kg / OC Sp. Heat of Copper = 390 J / kg / OC Hence, Rise in Temp. of Copper piece = (470 x 15 ) / 390 = 18.08 OC 8 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions S-6 Write down the parameters, which can be measured by following instruments: a) b) c) d) e) Ans S-7 Ans Stroboscope Sling Psychrometer Fyrite Tachometer Pitot tube a) Stroboscope b) Sling Psychrometer c) Fyrite d) Tachometer e) Pitot tube : Speed (Non Contact) : Dry & Wet Bulb Temperatures : O2 or CO2 in Flue Gases : Speed (Contact type) : Velocity pressure of moving gases An industrial plant is consuming 400 kW of power with a maximum demand of 520 kVA. The demand charge is Rs. 150/-per kVA. Determine the savings possible by improving power factor to 0.95 and payback period if investment on capacitor bank is Rs 1,50,000/-. =Rs. 1.50,000/- Simple Payback Period Ans : 400 / 520 = 0.77 : 520 * 150 = 78000/: 400 / 0.95 =421 kVA : 421 * 150 = Rs. 63150/=78000 63150 = Rs. 14850/- per Month Capacitor Investment S-8 Present Power Factor Present Demand Charges Rs. Future Demand with higher PF Modified Demand Charges Savings =1,50,000 / 14850 =10.1 Months A 100 tonnes per day capacity chlor-alkali plant produced 30,000 tonnes per annum (TPA) of caustic soda with annual energy consumption of 90 million kWh in the reference year 2009-10. During the year 201112, the annual production was 25,000 TPA, with an annual energy consumption of 80 million kWh. Calculate the Plant Energy Performance. Production Factor = 25000 / 30000 = 0.833 Reference year energy equivalent = Reference year energy use x Production factor = 90 x 0.833 = 75 million kWh 9 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions Excess Energy Consumption in 2011-2012 = 80 75 = 5 million kWh Plant Energy Performance (PEP) = [ (75 - 80) / 75 ] x 100 = (-) 6.67 % The performance in the year 2011 2012 is poor as compared to the reference year ------- End of Section - II --------- Section III: LONG DESCRIPTIVE QUESTIONS (i) (ii) L1 Marks: 6 x 10 = 60 Answer all Six questions Each question carries Ten marks A bag house is being used to remove dust from an air exhaust stream flowing at 100 m3/min. The dirty air contains 15 g/m3 of particles, while the cleaned air from the bag house contains 0.02 g/m3. The industry's operating permit allows the exhaust stream to contain as much as 0.9 g/m3. For various operating reasons, the industry wishes to bypass some of the dirty air around the bag house and blend it back into the cleaned air so that the total exhaust stream meets the permissible limit. Assume no air leakage and negligible change in pressure or temperature of the air throughout the process. Draw a schematic diagram and calculate the flow rate of air through the bag house and the mass of dust collected per day in kg. ANS Draw a flow diagram of the process as shown in Figure 1. In this problem two balances can be made, namely, flow rate of dust in g/m 3 and flow rate of air in m3/min. Balancing of flow rate of air in m 3/min is possible because the temperature and pressure of air remains constant in the system. 10 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions Write a balance for dust around the total system: Input = Output from bag house +Output in the mixed exhaust Or Dust removed from bag house (Z) = 100m3/min. x 15 g/m3 100m3/min. x 0.90 g/m3 =1410 g/min. Or Daily dust Output = 1410g/min x 24h/1d x 60min/1h x 1kg/1000g= 2030 kg Write a balance for airflow 100 = X+Y, where X and Yare bypass stream and flow through bag house, respectively. Write a balance for dust around B: 15X + 0.02Y = 0.9x100 Solving the last two equations X, the bypass stream = 5.9 m3/ min. Y, the flow through bag house = 94.1 m3/min. L2 a. Explain the difference between GCV and NCV. b. A gas fired water heater heats water flowing at the rate of 1.2 M 3 / hour from 20oC to 65oC. If the GCV of the gas is 4x10 7 J/kg, what is the rate of combustion gas in kg/hr. The efficiency of water heater as 80%, 11 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions a. The calorific value is the measurement of heat or energy produced, and is measured either as gross calorific value or net calorific value. The difference being the latent heat of condensation of the water vapour produced during the combustion process. Gross calorific value (GCV) assumes all vapour produced during the combustion process is fully condensed. Net calorific value (NCV) assumes the water leaves with the combustion products without fully being condensed. b) Mass of water heated = 1.20 M3 /hr = 1.2 x 1000 / 60 = 20 kg/min Heat required by Water = m x Cp x (t2 t1) = 20 kg/min x 4.187 x 103 J/kg/0C x (65-20) oC = 3.77 x 106 J/min Mass of Gas kg/min Mass 0f Gas Required L-3 = 3.77 x 106 / 0.8 /(4 x 107 ) = 0.1178 kg / min = 7.068 kg / Hr Answer any two of the following a) Benefits of Monitoring and Targeting system b) Duties and responsibilities of energy manager c) Energy substitution need not save energy: Explain with an example ANS a) Benefits of Monitoring and Targeting system The ultimate goal is to reduce energy costs through improved energy efficiency and management control measures. Other benefits include Identify and explain an increase or decrease in energy use Draw energy consumption trends (weekly, seasonal, operational) Improve energy budgeting corresponding to production plans Observe how the organization reacted to changes in the past Determine future energy use when planning changes in operations Diagnose specific areas of wasted energy Develop performance targets for energy management programs / energy action plans Manage energy consumption rather than accept it as a fixed cost that cannot be controlled. b) Duties and responsibilities of energy manager Responsibilities: 12 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions 1. Prepare an annual activity plan and present to management concerning financially attractive investments to reduce energy costs. 2. Establish an energy conservation cell within the firm and agree with management about the mandate and task of the cell. 3. Initiate activities to improve monitoring and process control to reduce energy costs. 4. Analyze equipment performance with respect to energy efficiency. 5. Ensure proper functioning and calibration of instrumentation required to assess level of energy consumption directly or indirectly. 6. Prepare information material and conduct internal workshops about the topic for other staff. 7. Improve disseminating of energy consumption data down to shop level or profit center of a firm. 8. Establish a methodology to accurately calculate the specific energy consumption of various products/services or activity of the firm. 9. Develop and manage training programme for energy efficiency at operating levels. 10. Co-ordinate nomination of management personnel to external programs. 11. Create knowledge bank on sectorial, national and international development on energy efficiency technology and management system and information denomination. 12. Develop integrated system of energy efficiency and environmental up gradation. 13. Wide internal and external networking 14. Co-ordinate implementation of energy audit/efficiency improvement projects through external agencies. 15. Establish and / or participate in information exchange with other energy managers of the same sector through association. Duties of Energy Manager: 1. Report to BEE and State level Designated Agency once a year. The information with regard to energy consumed and action taken in the recommendation of the accredited energy auditor, as per BEE Format. 2. Establish an improved data recording, collection and analysis system to keep track of energy consumption. 3. Provide support to Accredited Energy Audit Firm retained by the company for the conduct of energy audit. 4. Provide information to BEE as demanded in the Act, and with respect to the tasks given by the mandate, and the job description. 5. Prepare a scheme for efficient use of energy and its conservation and implement such scheme keeping in view the economic stability of the investment in such firm and manner as may be provided in the regulations of the Energy Conservation Act. c) Energy substitution need not save energy: Explain with an example The objective of energy substitution may be to reduce the use of costlier energy source to maximize the profit and to improve the efficiency of the process. Example: Replacement of conventional energy by renewable energy. 13 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions The efficiency of fuel oil fired systems will be higher than rice husk fired systems. Hence the total energy input to the systems will increase for rice husk fired systems. Even though material handling cost, specific fuel (energy) consumption increases for rice husk, this is a cheap locally available renewable form of energy which will bring down the fuel cost and transport cost compared to fuel oil. Hence Energy substitution need not save energy. Any other similar example. L-4 For the following tasks, durations, and predecessor relationships in the following activity table, Activity Description A B C D E F G H I a) b) c) d) e) Immediate Predecessor(s) --A A B D, C C F E, G H Optimistic (Weeks) 4 2 8 1 6 2 2 4 1 Most Likely (Weeks) 7 8 12 2 8 3 2 8 2 Pessimistic (Weeks) 10 20 16 3 22 4 2 12 3 Draw the network Calculate expected time for all tasks Calculate variance for all tasks Determine all possible paths and their estimated durations Identify the critical path Network diagram is shown below: 14 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions Formulas used for filling the above table: Te = (To + 4 Tm + Tp)/6 = (Tp To)/6 V = ((Tp To)/6)2 Activity Description A B C D E F G H I Immediate Predecessor(s) --A A B D, C C F E, G H Optimistic (Weeks) 4 2 8 1 6 2 2 4 1 Most Likely (Weeks) 7 8 12 2 8 3 2 8 2 Pessimistic (Weeks) 10 20 16 3 22 4 2 12 3 Te 7 9 12 2 10 3 2 8 2 Variance 1.00 9.00 1.78 0.11 7.11 0.11 0.00 1.78 0.11 The critical path is A C E H I Duration of critical path is 39 days . A - B D E H I A C E H I A C F G H I 7+9+2+10+8+2 = 38 7+12+10+8+2 = 39 7+12+3+2+8+2 = 34 The critical path is A C E H I Duration of critical path is 39 weeks. L-5 Write short notes on any two of the following: 15 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions a) Advantages of Demand Side Management (DSM) for end user and utility b) ISO 50001 Energy Management System c) Distinction between energy conservation and energy efficiency ANS a) Advantages of DSM End user: End use demand can be shifted from peak to off peak hours thereby reducing the need for buying expensive energy during peak hours Helps better manage the load curve and thus reduce the demand improve the profitability Utility: Energy saving through DSM is treated same as new additions in supply side Can reduce the capital needs for power capacity expansion Improved loading of utility power plants and hence improved efficiency and profitability b) ISO 50001 features ISO 5001involves the following features: Goal outlined in Energy policy Objectives to achieve the goal Targets which are more specific than objectives which outlines actual energy conservation measures to be implemented. An objective may have one or more targets. Action plans to implement the targets which outline actions, time frame, responsibility and resources for implementation. All the above with other related documents are audited during internal and external audits. c) Energy conservation and Energy efficiency Energy conservation is achieved when energy consumption is reduced in physical terms as a result of productivity increase or technology change. On the other hand, energy efficiency is achieved when energy intensity is reduced in a specific product, process or area of production without affecting the output, consumption or comfort levels. Energy efficiency means using less energy to perform the same function. Energy efficiency promotion will contribute to energy conservation and therefore a part of energy conservation policies. 16 _______________________ Bureau of Energy Efficiency Paper 1 Set A Solutions L-6 It is proposed to install a heat recovery device in a process industry. The capital cost of installing the device is Rs.2,00,000 and after 5 years its salvage value is envisaged at Rs.15,000. The savings accrued by the heat recovery device are as shown below. Determine the net present value after 5 years for a discount rate of 8%. Year 1 2 3 4 5 Savings (Rs.) 70,000 60,000 60,000 50,000 50,000 Ans Year Discount factor Capital for 8% Investment (Rs.) Net (Rs.) savings Present value (Rs.) 0 1.00 1 0.926 70000 +64820 2 0.857 60000 +51420 3 0.794 60000 +47640 4 0.735 50000 +36750 5 0.681 50000 +15000 +44265 -200000 -200000 NPV=+44895 It is evident that over a 5-year life-span the net present value of the project is 44895. -------- End of Section - III --------- 17 _______________________ Bureau of Energy Efficiency

Formatting page ...

Formatting page ...

Top Contributors
to this ResPaper
(answers/comments)


Bob Bird

(4)

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

 

  Print intermediate debugging step

Show debugging info


 


Tags : Bureau of Energy Efficiency, BEE, National Productivity Council of India, NPC, Energy Audit, Certified Energy Manager, Certified Energy Auditor, EM & EA, bee papers, bee sample papers, bee books, portal for bee india, bee question bank, bee question papers with answers, bee model test papers, solved board question papers of last year, previous years solved question papers, free online solved question paper, india sample questions papers, last 10 years papers, guess sample questions papers, important questions, specimen / mock papers, 2020, 2019, 2018, 2017, 2016, 2015, 2014, 2013, 2012, 2011, 2010, 2009, 2008, 2007, 2006, 2005.  


© 2010 - 2025 ResPaper. Terms of ServiceContact Us Advertise with us

 

bee_energy chat